The RO10K is a modular reverse osmosis system that produces up to 10,300 gallons per day of spot-free rinse water from a single 8-inch commercial membrane.
It fits new builds and replacements, and works with compatible existing storage, repressurization and pretreatment.
Why Operators Choose RO10K
Dependable spot-free production. Clear system visibility.
RO10K gives operators a direct view of water quality, flow and pressure, with accessible components for routine inspection and service.
8" Commercial Membrane
A large-format commercial membrane provides up to 10,300 GPD of spot-free rinse water production with a simplified single-membrane design
Built-In System Monitoring
The controller displays permeate TDS, while separate flow meters and pressure gauges help operators check production and system performance
Automatic Membrane Flushing
Programmed low-pressure flushes at startup and shutdown help reduce membrane fouling and maintain performance
Service-Friendly Design
System components are organized on an open stainless steel frame to support routine inspection, maintenance, and service
Built for Everyday Operation
Practical design. Reliable performance.
Grundfos Production Pump
A 3 HP Grundfos pump pressurizes feed water for the reverse osmosis process
Integrated Sediment Filtration
An onboard sediment filter removes suspended solids before they reach the RO membrane, helping protect the membrane and support system reliability
Manual Flow Adjustment
Reject and recirculation needle valves let technicians set flow and recovery during commissioning and service
Modular System Configuration
Use new or compatible existing pretreatment, RO storage and repressurization equipment, selected to suit your installation
How the RO10K Works
The RO10K turns softened feed water into spot-free rinse water, stores it, and supplies your final rinse arch.
Softenedfeed water Carbon filter RO10K RO storage tank Reject storage tank Repress pump Repress pump Spot-free rinseTo the wash Reject reuseOptional, to the wash
- 01Carbon filterPretreat
Feed water is softened and dechlorinated before it reaches the RO10K. Free chlorine must be below 0.1 ppm to protect the membrane, usually with carbon filtration.
- 02RO10KFilter & purify
An onboard sediment filter removes suspended solids, then a 3 HP Grundfos pump pushes water through a single 8-inch commercial membrane that removes up to 99% of dissolved solids.
- 03Storage tanksStore
Purified water flows into your RO storage tank at up to 7.15 GPM, and tank level switches start and stop production. Reject flow and recovery are set with needle valves during startup.
- 04Repress pumpsRepressurize
A repressurization pump sends stored RO water out at the pressure your wash needs.
- 05Back to the washRinse
Spot-free water feeds your final rinse arch. Reject water can optionally be stored and reused in suitable wash applications.
Specifications
| Specification | Value |
|---|---|
| Performance | |
| Production (GPD)* | 10,300 |
| Membranes (Qty) | 1 |
| Permeate Flow* | 7.15 GPM |
| Reject Flow* | Variable |
| Pump & Connections | |
| Production Pump | 3 HP |
| Inlet Size | 1" hose barb |
| Permeate Outlet | 0.5" hose barb |
| Reject Outlet | 0.5" hose barb |
| Water Requirements | |
| Feed Water Temperature | 40°F–80°F |
| Feed Water Supply | 20 GPM @ 20–30 psi |
| Electrical | |
| Production Pump Power** | 480 VAC / 3 PHOptional: 208 VAC / 3 PH |
| Control Power Supply | 110 VAC / 1 PH |
| Max Current | 4 A (480V) / 7.5 A (208V) |
| Dimensions | |
| Main Skid (W × H × D) | 24" × 73.75" × 37" |
| Site Requirements | |
| Pretreatment | Softened, dechlorinated feed waterFree chlorine below 0.1 ppm, usually with carbon filtration |
| Storage & Delivery | RO storage tank and repressurization pump (new or compatible existing) |
* Rated performance value; actual output varies with feed water temperature and quality.
** Optional 208 VAC / 3-phase configuration available.
RO10K Product Guide
Download a printable overview of RO10K, including key features, specifications, and configuration information
RO10K FAQs
How much spot-free rinse water does the RO10K produce?
The RO10K produces up to 10,300 gallons per day (7.15 GPM) of spot-free rinse water. Production rates are based on softened feed water at 77°F and will vary with incoming water temperature and conditions.
What water quality does the RO10K produce?
The RO10K uses reverse osmosis to remove up to 99% of dissolved solids and impurities from incoming water. For spot-free rinse applications, RO water should measure 10 ppm TDS or less. An onboard TDS sensor continuously monitors permeate water quality and displays the reading on the system controller.
Does the RO10K require a storage tank?
Yes. RO10K produces permeate into an RO storage tank, and tank level switches control production. A matched repressurization pump delivers the stored water to the wash. New or compatible existing storage and delivery equipment can complete the installation.
Can I use my existing RO storage tanks and repress pump?
Compatible existing equipment may be used. Our team will review tank capacity, level controls, delivery pressure and rinse demand to determine the right configuration for your site. New carbon filtration, storage tanks and repressurization equipment are also available.
What pretreatment does the RO10K require?
Pretreatment depends on the quality of the incoming water. The RO10K requires softened feed water and free chlorine below 0.1 ppm. Depending on site water conditions, pretreatment may also include carbon filtration, iron filtration, or other water treatment equipment to protect the RO membrane and maintain system performance.
What maintenance does the RO10K require?
Inspect the system daily for leaks or wear. Check free chlorine and spot-free TDS weekly, and inspect the production pump motor every 500 operating hours or three months, whichever comes first. Keep pretreatment equipment maintained and follow the full service schedule in the manual. Automatic startup and shutdown flushes help reduce membrane fouling between service visits.
Complete Your Backroom
Reclaim Gen2
Cleaner reclaim water with greater control over water reuse and day-to-day system operation
dispenseIT Gen2
Chemical delivery in 10, 15, 20 or 25-function configurations, floor or wall mount
HP Pump Stands
Reliable pressure delivery for arches, manifolds, underbody, and other high-pressure wash functions
What to Expect
Discuss Your Application
We’ll review your wash, water conditions, spot-free rinse needs, and existing backroom equipment to determine if the RO10K is the right fit
Plan Your System
We’ll identify the supporting components needed for your site and determine how the RO10K will integrate with your backroom
Installation & Startup
We’ll work with your installation team or distributor to support proper installation, setup, and startup of your RO10K