Installation Requirements #
- The dispenseIT requires the following components to operate
- dispenseIT assembly
- Control system
- Electrical supply
- Water supply
- Air supply
Space Requirements #
- Floor Mount Unit
- 15 Function
- 55โ W x 24โ D x 60โ H
- 20 Function
- 66โ W x 24โ D x 60โH
- 15 Function
- Wall Mount Unit
- 15 Function
- 67โ W x 16โ D x 39โ H
- 20 Function
- 78โ W x 16โ D x 39โ H
- Pump (can be remotely mounted)
- 16โ W x 16โ D x 48โ H
- Supplied with 8โ hose
- 15 Function
Operating Pressures #
- Water
- 200 psi (factory set) –ย Range of 100-200 psi
- Air
- 85 psi (factory set) –ย Range of 85-100 psi
Electrical Supply #
- Pump
- 208/230/240 or 480 VAC 3ph
- 5HP 17.5 amps @208 – 15.2 ampsย @ 230/240 or 7.6 amps @ 480
- 7.5HP 25.3 amps @ 208 – 22 ampsย @ 230/240 or 11 amps @ 480
- Controls
- 24vac 1 amp per function
- 120vac 1/4 amp per function
Water Pump Supply #
- 5HP Pump
- Minimum 1.5โ ID line
- Inlet static pressure 5-90 psi
- Pumps fed from a โday tankโ
- Water level should be a minimum of 60โ above inlet of pump
- 7.5HP Pump
- Minimum 2โ ID line
- Pumps fed from a โday tankโ
- Water level should be a minimum of 60โ above inlet of pump
Air Supply #
- Air
- 1/2โ poly tube connections
- 20CFM @ 100 psi from building compressed air system
Product Lines #
- Liquidย Connection
- 1/2โ poly tube
- 3/4โ barb for high flow applications –ย Applications greater than 5.5 gpm
- Air Connection
- 3/8″ poly tube