dispenseIT Manual – Installation Requirements

Installation Requirements #

  • The dispenseIT requires the following components to operate
    • dispenseIT assembly
    • Control system
    • Electrical supply
    • Water supply
    • Air supply

Space Requirements #

  • Floor Mount Unit
    • 15 Function
      • 55” W x 24” D x 60” H
    • 20 Function
      • 66” W x 24” D x 60”H
  • Wall Mount Unit
    • 15 Function
      • 67” W x 16” D x 39” H
    • 20 Function
      • 78” W x 16” D x 39” H
    • Pump (can be remotely mounted)
      • 16” W x 16” D x 48” H
      • Supplied with 8’ hose

Operating Pressures #

  • Water
    • 200 psi (factory set) – Range of 100-200 psi
  • Air
    • 85 psi (factory set) – Range of 85-100 psi

Electrical Supply #

  • Pump
    • 208/230/240 or 480 VAC 3ph
    • 5HP 17.5 amps @208 – 15.2 amps @ 230/240 or 7.6 amps @ 480
    • 7.5HP 25.3 amps @ 208 – 22 amps @ 230/240 or 11 amps @ 480
  • Controls
    • 24vac 1 amp per function
    • 120vac 1/4 amp per function

Water Pump Supply #

  • 5HP Pump
    • Minimum 1.5” ID line
    • Inlet static pressure 5-90 psi
    • Pumps fed from a “day tank”
    • Water level should be a minimum of 60” above inlet of pump
  • 7.5HP Pump
    • Minimum 2” ID line
    • Pumps fed from a “day tank”
    • Water level should be a minimum of 60” above inlet of pump

Air Supply #

  • Air
    • 3/8” poly tube connections
    • 20CFM @ 100 psi from building compressed air system

Product Lines #

  • Liquid  Connection
    • 1/2” poly tube
    • 3/4” barb for high flow applications – Applications greater than 5.5 gpm
  • Air Connection
    • 3/8″ poly tube